Home Power Facts

EcoFlow DELTA 2 Max vs Jackery HomePower 2000 Plus v2

The EcoFlow DELTA 2 Max delivers more usable capacity than the Jackery HomePower 2000 Plus v2 (about 1,800 Wh vs 1,638 Wh). A typical refrigerator runs about 27 h on the EcoFlow DELTA 2 Max and 24.6 h on the Jackery HomePower 2000 Plus v2.

Specs verified 2026-10-18. Every value below links to its source.

Where they differ

Better on 3 of 5

EcoFlow DELTA 2 Max

  • EcoFlow DELTA 2 Max: more usable capacity (1,800 Wh vs 1,638 Wh, Jackery HomePower 2000 Plus v2).
  • EcoFlow DELTA 2 Max: lower price per usable Wh ($0.72 vs $0.73, Jackery HomePower 2000 Plus v2), the fairest value measure across sizes.
  • EcoFlow DELTA 2 Max: more solar input (1,000 W vs 800 W, Jackery HomePower 2000 Plus v2).
Check EcoFlow DELTA 2 Max price on Amazon

Better on 2 of 5

Jackery HomePower 2000 Plus v2

  • Jackery HomePower 2000 Plus v2: lighter (41.5 lb vs 50 lb, EcoFlow DELTA 2 Max).
  • Jackery HomePower 2000 Plus v2: lower list price (1,199 USD vs 1,299 USD, EcoFlow DELTA 2 Max).
Check Jackery HomePower 2000 Plus v2 price on Amazon
Affiliate links: we may earn a commission, at no cost to you. As an Amazon Associate I earn from qualifying purchases.

Specs side by side

SpecEcoFlow DELTA 2 MaxJackery HomePower 2000 Plus v2
Rated capacity2,048 Wh[source]Spec table: 'Capacity 2048Wh'.2,048 Wh[source]Manual (HomePower 2000 Plus, model JHP-2000A, V2) Specifications: 'Capacity 2048 Wh (40Ah/51.2V DC)'. Page: '2048Wh Capacity'.
Usable capacity (measured)1,800 Wh[source]StorageReview measured 1,800 Wh through the AC inverter at a 350 W load (120 V unit). The Solar Lab reports 86% inverter efficiency but gives no Wh figure.Not publishedNo independent measured test found (searched 2026-10-19: outdoorgearlab, thesolarlab, cnet, wirecutter, techradar, general web). backuppowerhub.com covers it with spec-based runtime math only.
AC continuous output2,400 W[source]Spec table: 'AC Output 6 outlets, 2400W total (Surge 4800W)'. X-Boost: 3,400 W.2,400 W[source]Manual: '4 × AC Output 120V~ 60Hz, 20A Max, 2400W Rated per port, 2400W in Total, 4800W Surge Peak'. Page: '2400W Output'.
AC surge output4,800 W[source]Spec table and user manual both say 'surge 4,800W'. Marketing text on the same page cites 'up to 3400W' (that is the X-Boost figure, not surge).4,800 W[source]Manual: '2400W in Total, 4800W Surge Peak'.
240 V outputNo[source]Official manual: 'AC (x6) Pure sine wave, 2,400W total (surge 4,800W) 120V~ 50/60Hz'. 120 V only; the product page does not state outlet voltage.No[source]All AC outlets are 120V: '4 × AC Output 120V~ 60Hz, 20A Max'. The manual describes no 240V or parallel mode.
Battery chemistryLiFePO4[source]Spec table: 'LFP (LiFePO4 battery)'.LiFePO4[source]Manual Specifications: 'Cell Chemistry LiFePO4'. Page: '6000+ LFP battery cycles'.
Cycle life3,000 cycles to 80%+ capacity[source]Spec table: '3000 cycles to 80+% capacity'.6,000 cycles to 70%+ capacity[source]Manual Specifications: '6000 cycles to 70%+ capacity'.
AC charging1,800 W[source]Spec table: 'AC Charging X-stream Fast Charge 1800W, 15A'. Manual agrees ('X-Stream max. 1,800W 15A').Not publishedNo wattage stated officially. Manual: 'Charge Mode: 100V-120V~ 60Hz, 15A Max'. The manual describes an emergency charging mode but gives no wattage.
Max solar input1,000 W[source]Spec table: '11-60V 15A, single port 500W; dual port 1,000W'.800 W[source]Manual: '2 × DC8020 Ports 16V-60V⎓12A Max, Double to 21A / 800W Max'.
ExpandableYes[source]Spec table: 'Supports up to two DELTA 2 Max Smart Extra Batteries / DELTA Max Smart Extra Battery'.Yes[source]Manual: 'This product can support up to 5 battery packs'. Page: 'Please note that the Battery Pack 2000 Plus is not compatible with the HomePower 2000 Plus V2. The HomePower 2000 Plus V2 is only compatible with the Battery Pack 2000 Plus V2.'
UPS / EPS switchover20 ms[source]Official US product page: '<20ms UPS Auto-Switch' and 'updated 20 ms UPS feature'. The original user manual V1.0 says 'within 30ms'. Not listed in the us.ecoflow.com spec table.10 ms[source]Manual: 'the switchover time from grid power to the internal battery is 10 ms' and 'This product does not support 0 ms switching'. In UPS (bypass) mode output is '100V-120V~ 60Hz, 15A Max'.
Weight50 lb[source]Spec table: 'Net weight (lbs) 50 lbs' / '23kg'.41.45 lb[source]Manual: 'About 41.45 lbs/18.8 kg'.
Warranty5 years[source]'5-Year warranty'.5 years[source]Manual: standard warranty '36 months' plus 2-year extended warranty. Page: '3-Year Warranty + 2 Extra Years Free — Exclusively at jackery.com'.
List price$1,299[source]Standalone variant compare-at price $1,299.00; sale price $1,049.00 seen 2026-10-18 (a members-only 'Free Bag' variant shows compare-at $1,099).$1,199[source]Standalone unit compare-at (list) price $1,199.00, sale price $1,069.00, seen 2026-10-19. The bundle with Battery Pack 2000 Plus v2 is shown sold out ($1,549 sale / $1,889 list).
Usable capacity used for runtimes1,800 Wh1,638 Wh (est. 80%)

Runtime on one charge

ApplianceEcoFlow DELTA 2 MaxJackery HomePower 2000 Plus v2
Refrigerator27 h24.6 h
Chest freezer3.1 days2.8 days
CPAP (no humidifier)40 h36.4 h
CPAP with heated humidifier20 h18.2 h
Sump pump (1/3 hp)2.8 h2.5 h
Sump pump (1/2 hp)1.9 h1.8 h
Gas furnace blower (1/2 hp)3.3 h3 h
Window AC (5,000 BTU)5.2 h4.7 h
Microwave2 h1.8 h
Coffee maker1.5 h1.4 h
Laptop charger30 h27.3 h
Phone charger3.8 days3.4 days
Wi-Fi router / modem5 days4.6 days
TV (LED, 32-55 inch)26.5 h24.1 h
LED light bulb (each)8.3 days7.6 days
Space heater1.2 h1.1 h
Oxygen concentrator (home, 5 L/min)5.1 h4.7 h
Starlink (Standard kit)20.5 h18.6 h
Desktop PC + monitor20 h18.2 h
Electric blanket (queen)6.9 h6.3 h
Box fan (20 inch)21.7 h19.7 h
Dehumidifier (35-50 pint)3.7 h3.4 h
Portable air conditioner (8,000-10,000 BTU)1.5 h1.4 h
Electric kettle1.2 h1.1 h
Portable induction cooktop (single burner)1 h0.9 h
Air fryer1.2 h1.1 h
Mini fridge (compact, ~3 cu ft)3 days2.7 days
Garage door opener2.5 h2.3 h

Runtime = usable capacity ÷ average draw, the same formula for both models (no idle draw added to either), after checking continuous output and startup surge. Usable capacity is an independent test's measured figure, or 80% of rated where none exists. See the methodology.