Home Power Facts

Anker SOLIX C1000 vs BLUETTI Elite 100 V2

The Anker SOLIX C1000 delivers more usable capacity than the BLUETTI Elite 100 V2 (about 897 Wh vs 890 Wh). A typical refrigerator runs about 13.5 h on the Anker SOLIX C1000 and 13.4 h on the BLUETTI Elite 100 V2.

Specs verified 2026-10-18. Every value below links to its source.

Where they differ

Better on 2 of 7

Anker SOLIX C1000

  • Anker SOLIX C1000: more usable capacity (897 Wh vs 890 Wh, BLUETTI Elite 100 V2).
  • Anker SOLIX C1000: faster AC charging (1,300 W vs 1,200 W, BLUETTI Elite 100 V2).
Check Anker SOLIX C1000 price on Amazon

Better on 5 of 7

BLUETTI Elite 100 V2

  • BLUETTI Elite 100 V2: higher surge rating (3,600 W vs 2,400 W, Anker SOLIX C1000).
  • BLUETTI Elite 100 V2: lighter (25.3 lb vs 28.4 lb, Anker SOLIX C1000).
  • BLUETTI Elite 100 V2: lower list price (499 USD vs 599.99 USD, Anker SOLIX C1000).
  • BLUETTI Elite 100 V2: lower price per usable Wh ($0.56 vs $0.67, Anker SOLIX C1000), the fairest value measure across sizes.
  • BLUETTI Elite 100 V2: more solar input (1,000 W vs 600 W, Anker SOLIX C1000).
Check BLUETTI Elite 100 V2 price on Amazon
Affiliate links: we may earn a commission, at no cost to you. As an Amazon Associate I earn from qualifying purchases.

Specs side by side

SpecAnker SOLIX C1000BLUETTI Elite 100 V2
Rated capacity1,056 Wh[source]Tech Specs 'Capacity: 1056Wh'. This is the original C1000 (A1761), not the C1000X (separate page, /products/a1761111) or the C1000 Gen 2 (1,024 Wh). The US page shows the unit as 'Sold Out' on 2026-10-18.1,024 Wh[source]Manual V5.1 spec table: 'Battery Capacity 1,024Wh (20Ah)'. The product page comparison table agrees.
Usable capacity (measured)897 Wh[source]OutdoorGearLab (US unit, AC output) measured 897 Wh, about 85% of rated. ComputerBase (EU 230 V unit) measured 993 Wh at 500 W and 954 Wh at 2,000 W; the lower figure is used.890 Wh[source]OutdoorGearLab measured '890 Wh out of its advertised 1,024 Wh' (87%). The test load is not stated. TechReviewer.de (apparently the 230 V EU unit) drew 946 Wh at a constant 500 W load and says usable capacity falls to about 80% at loads in the tens of watts. The lower figure is used.
AC continuous output1,800 W[source]'AC Continuous Output: 1800W Pure Sine Wave'.1,800 W[source]Manual spec table: 'AC Output 1,800W Max., 120V, 15A Max., 50Hz / 60Hz'. Power Lifting mode runs resistive loads up to 2,700 W.
AC surge output2,400 W[source]'AC Surge Output: 2400W' (SurgePad, for heat-generating devices).3,600 W[source]Official FAQ A4: '1,800W continuous AC output, 2,700W lifing power, and up to 3,600W surge with HyperVolt™'. The page meta description also says 'surge 3600W'. The US manual spec table gives no surge figure.
240 V outputNo[source]Official spec data 'AC Output Voltage: 120V'; no 240 V output.No[source]Manual spec table: 'AC Output 1,800W Max., 120V, 15A Max.' No 240 V output.
Battery chemistryLiFePO4[source]'LiFePO4 (Lithium Iron Phosphate)'.LiFePO4[source]Manual spec table: 'Battery Type LiFePO4'.
Cycle life3,000 cycles to 80% capacity[source]'Battery Life Cycles: 3,000 (80% Capacity)'.4,000+ cycles to 80% capacity[source]Product page comparison table: '4,000+ Cycles to 80% Original Capacity'.
AC charging1,300 W[source]'AC Input Recharge: 1,300W Max'; full charge in 58 min (UltraFast).1,200 W[source]Manual spec table: 'AC Charging 1,200W Max. (80% in 45 mins @25°C / 77°F)'; 'AC Input 1,800W Max. (Charging + Bypass)'; 'AC + DC Charging 1,200W Max.'
Max solar input600 W[source]'600W Max, 11-60V MPPT'.1,000 W[source]Manual spec table: 'DC Input 1,000W Max., 12V-60V, 20A Max.' Note that AC + DC charging together is still capped at 1,200 W.
ExpandableYes[source]'Increase the capacity of C1000 with an extra 1,056Wh' via the BP1000 expansion battery (1 max).No[source]No expansion battery port. Official FAQ A18 says B80 batteries can be connected with an 'Aviation to XT60' cable, but only in the B80's 'Power Bank Mode', which charges the unit through its DC input rather than adding capacity.
UPS / EPS switchover20 ms[source]Tech Specs 'UPS Switch Time: <20ms'.10 ms[source]Manual spec table: 'Uninterruptible Power Supply (UPS) Switchover Time 10 ms'. The product page says '10ms UPS Backup' and the comparison table '≤10 ms'.
Weight28.44 lb[source]'Net Weight: 28.44 lb / 12.9 kg'.25.3 lb[source]Manual spec table: 'About 11.5kg (25.3lbs)'. The product page FAQ also says '25.3lbs(11.5kg )'; its comparison table rounds to '11.5kg (25lbs)'.
Warranty5 years[source]'Warranty: 5-Year Warranty'.5 years[source]Official FAQ A7: 'it comes with a 5-year warranty'.
List price$599.99[source]Seen 2026-10-18: unit 'Sold Out', so the page shows no price; the store's product data lists the standalone variant at $599.99 with no compare-at price. No sale price shown.$499[source]US$499.00 for the standalone unit, seen 2026-10-19. No compare-at price is shown (store data lists 499 as both price and list price), and it is in stock. A 'Bio-based' shell variant is shown at $499 against $699.
Usable capacity used for runtimes897 Wh890 Wh

Runtime on one charge

ApplianceAnker SOLIX C1000BLUETTI Elite 100 V2
Refrigerator13.5 h13.4 h
Chest freezer36.5 h36.2 h
CPAP (no humidifier)19.9 h19.8 h
CPAP with heated humidifier10 h9.9 h
Sump pump (1/3 hp)1.4 h1.4 h
Sump pump (1/2 hp)1 h1 h
Gas furnace blower (1/2 hp)1.6 h1.6 h
Window AC (5,000 BTU)2.6 h2.6 h
Microwave1 h1 h
Coffee maker0.7 h0.7 h
Laptop charger15 h14.8 h
Phone charger44.9 h44.5 h
Wi-Fi router / modem2.5 days2.5 days
TV (LED, 32-55 inch)13.2 h13.1 h
LED light bulb (each)4.2 days4.1 days
Space heater0.6 h0.6 h
Oxygen concentrator (home, 5 L/min)2.6 h2.5 h
Starlink (Standard kit)10.2 h10.1 h
Desktop PC + monitor10 h9.9 h
Electric blanket (queen)3.5 h3.4 h
Box fan (20 inch)10.8 h10.7 h
Dehumidifier (35-50 pint)1.8 h1.8 h
Portable air conditioner (8,000-10,000 BTU)0.7 h0.7 h
Electric kettle0.6 h0.6 h
Portable induction cooktop (single burner)0.5 h0.5 h
Air fryer0.6 h0.6 h
Mini fridge (compact, ~3 cu ft)35.9 h35.6 h
Garage door opener1.2 h1.2 h

Runtime = usable capacity ÷ average draw, the same formula for both models (no idle draw added to either), after checking continuous output and startup surge. Usable capacity is an independent test's measured figure, or 80% of rated where none exists. See the methodology.